Difference between revisions of "MWLLFlowNodes:SetAmbientTemp"

From MechWarrior: Living Legends Wiki
Jump to: navigation, search
m
m
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{MWLLFlowNode|
+
{| class="wikitable" style="border:1px solid #250b2d; text-align:left; width:500px;" cellpadding="1" cellspacing="0" rules="all" align="right"
| Image = [[File:SetAmbientTemp.png]]
+
! colspan="3" style="background:#2a2a2a; text-align:center; font-size:12pt" | Set Ambient Temp
| Name =SetAmbientTemp
+
|-
|
+
| '''Name''' || '''Type''' || '''Description'''
{{FlowIn|AmbientTemperature|Float|Temperature which will be set on unit}}
+
|-
{{FlowIn|LocalConductivityFactor|Float|Speed in which temperature will change (affects weapons cooldown)}}
+
|AmbientTemperature
{{FlowIn|IsLiquid|Bool|Make this temperature change work only on submerged vehicles if set to true}}
+
|Float
|}}
+
|Temperature which will be set on unit
 +
|-
 +
|LocalConductivityFactor
 +
|Float
 +
|Speed in which temperature will change (affects weapons cooldown
 +
|-
 +
|IsLiquid
 +
|Bool
 +
|Make this temperature change work only on submerged vehicles if set to true
 +
|-
 +
!colspan="3" style="text-align:center" | [[File:SetAmbientTemp.png]]
 +
|-
 +
|}
  
  
Line 16: Line 28:
 
#Set it's height to desired level - for Mechs 20 should work well
 
#Set it's height to desired level - for Mechs 20 should work well
 
#Add Entity -> Triggers -> AreaTrigger
 
#Add Entity -> Triggers -> AreaTrigger
#Select AreaShape, below Target box click "Pick", click on the AreaTrigger <br>[[File:SetAmbientTemp Example1a.png|300px]]
+
#Select AreaShape, below Target box click "Pick", click on the AreaTrigger <br>[[File:SetAmbientTemp_Example1a.png|300px]]
 
#Select AreaTrigger, click "Create" Flow Graph
 
#Select AreaTrigger, click "Create" Flow Graph
#Create flowgraph as follows:<br>[[File:SetAmbientTemp Example1b.png]]<br>Note: Remember to have flowgraph ''MultiPlayer Options'' as ''ClientOnly'' (set by default) - otherwise it won't work.
+
#Create flowgraph as follows:<br>[[File:SetAmbientTemp_Example1b.png]]<br>Note: Remember to have flowgraph ''MultiPlayer Options'' as ''ClientOnly'' (set by default) - otherwise it won't work.
  
 
{{Navbox FlowNodes}}
 
{{Navbox FlowNodes}}
  
 
[[Category:FlowNodes]]
 
[[Category:FlowNodes]]

Latest revision as of 04:08, 15 August 2017

Set Ambient Temp
Name Type Description
AmbientTemperature Float Temperature which will be set on unit
LocalConductivityFactor Float Speed in which temperature will change (affects weapons cooldown
IsLiquid Bool Make this temperature change work only on submerged vehicles if set to true
SetAmbientTemp.png


SetAmbientTemp is the MWLL Flowgraph Node setting temperature (it won't be visible as "ext" (external) in HUD, only cause Core temperature to raise)

Examples

  1. Add Area -> Shape
  2. Set it's height to desired level - for Mechs 20 should work well
  3. Add Entity -> Triggers -> AreaTrigger
  4. Select AreaShape, below Target box click "Pick", click on the AreaTrigger
    SetAmbientTemp Example1a.png
  5. Select AreaTrigger, click "Create" Flow Graph
  6. Create flowgraph as follows:
    SetAmbientTemp Example1b.png
    Note: Remember to have flowgraph MultiPlayer Options as ClientOnly (set by default) - otherwise it won't work.